Project Scope:
Significantly reduce person-rem exposure.
Greatly simplify future heat exchanger (HX) replacement and maintenance.
Description:
Reduce routine personnel exposure along a high traffic access route, and exposure during future HX change out.
Shield assembly serves as locked high radiation area barrier.
Can be moved as a pre-assembled unit into final location.
Contains leaks and provides means of drainage.
As an exposure-saving measure, HX mounts are unfastened with minimal effort, from a distance, and without significant shielding disassembly.
Carbon steel plate is used for cost-effective fabrication and increased strength.
Sliding split shield is used to cover the access ports for pipe connections and to accommodate alignment.